FSP Spoke Type Load Cell

3-Year Warranty Free Installation Support
5,0 / 5 (16 reviews)
FSP Spoke Type Load Cell
atexexproof
ip68
3year
rohs
ce
iso
Made in Türkiye
ISO 9001CERoHS3-Year WarrantyIP 68ATEX / Ex-proof
Capacity1 – 100 Ton
Accuracy classC1
Protection classIP 68 / IP 67
Safe overload150 % FS
Documents
3-Year Warranty Free Installation Support

Description

FSP is a load cell has the features of double direction operation (compression-tensile) produced with high accuracy and high precision.

It is produced completely our factory in Konya with capacity options from 1 ton to 100 tons.

Alloy steel is cleaned with the sandblasting method after being cured by heat treatment and after it is completely homogenized, it is coated with nickel in order to be more resistant to corrosion, so it offers trouble-free use in the most difficult conditions.

Optionally available in stainless chrome steel.

Technical Specification

Go to documents
Capacity : 1 – 100 Ton
Accuracy Class (ISO 376) : C1
Minimum Load : 0 kg
Linearity : ≤ ±0.05 %FS
Repeability : ≤ ±0.05 %FS
Total Error : 0.05 ~ 0.25
Output Sensitivity (FS) : 2.00 mV/V ± 0.1 % F.S.
Zero Balance : ≤ ± 0.1 %FS
Input Resistance : 750 Ω ± 30 Ω
Output Resistance : 703 Ω ± 5 Ω
Isolation Resistance : ≥ 5000 MΩ (100VDC)
Compansated Temperature : -10 … +40 °C
Operating Temperature : -30 … +70 °C
Excitation, Recommended Voltage : 10 VDC
Maximum Excitation Voltage (Umax) : 15 VDC
Safe Overload : 150 % FS
Ultimate Overload : 300 % FS
Ingress Protection (EN60529) : IP 68 / IP 67
Element Material : Alloyed Steel / Stainless steel
Cable : 4x0.22 mm²

Metrological data

Capacity
1 – 100 Ton
Accuracy Class (ISO 376)
C1
Linearity
≤ ±0.05 %FS
Output Sensitivity (FS)
2.00 mV/V ± 0.1 % F.S.
Zero Balance
≤ ± 0.1 %FS

Electrical data

Input Resistance
750 Ω ± 30 Ω
Output Resistance
703 Ω ± 5 Ω
Isolation Resistance
≥ 5000 MΩ (100VDC)
Excitation, Recommended Voltage
10 VDC
Maximum Excitation Voltage (Umax)
15 VDC

Environmental data

Compansated Temperature
-10 … +40 °C
Operating Temperature
-30 … +70 °C
Ingress Protection (EN60529)
IP 68 / IP 67

Mechanical data

Safe Overload
150 % FS
Ultimate Overload
300 % FS
Element Material
Alloyed Steel / Stainless steel
Cable
4x0.22 mm²

Other

Minimum Load
0 kg
Repeability
≤ ±0.05 %FS
Total Error
0.05 ~ 0.25

Application Area

Application Areas

  • Force testing machines
  • Tensile breakout testing machines

Documents

Technical Documents

Media

Related Products

View full category