WTH Compression Load Cell





Description
The WTH Load Cell is a compression-type load cell made of high-quality stainless steel or special alloy steel with a capacity ranging from 10 to 1000 tons.
The alloy steel is heat-treated, sandblasted, and then coated with nickel to provide greater corrosion resistance and years of trouble-free use in industrial environments.
The WTH load cell can be easily used in multiple fields with its specially designed mounting kits.
Unlike other compression-type load cells, the WTH load cell is designed with a column structure that has more strain gauges, making it more stable and sensitive under heavier loads.
In addition to the standard 4x0.22mm cable, it can be produced with armored or Ex-proof silicone cables as an additional option.
Armored cables are more resistant to external factors and provide complete protection against rodent damage.
Technical Specification
| Capacity | : 100, 200, 300, 500, 750, 1000 Ton |
| Accuracy Class | : C1 |
| Minimum Load | : 0 kg |
| Maximum Intervals (nLC) | : 1000 |
| Minimum Verification Interval | : Emax/5000 |
| Total Error | : ±0.05 %FS |
| Output Sensitivity (FS) | : 2.00 ± 0.05mV/V |
| Zero Balance | : ± 1 %FS |
| Input Resistance | : 400 Ω ± 30 Ω |
| Output Resistance | : 350 Ω ± 5 Ω |
| Isolation Resistance | : ≥ 5000 MΩ (100VDC) |
| Compansated Temperature | : -10 … +40 °C |
| Operating Temperature | : -30 … +70 °C |
| Excitation, Recommended Voltage | : 10 VDC |
| Maximum Excitation Voltage (Umax) | : 15 VDC |
| Safe Overload | : 150 % FS |
| Ultimate Overload | : 300 % FS |
| Ingress Protection (EN60529) | : IP 66 |
| Element Material | : Alloyed Steel |
| Cable | : 4x0.22 mm² |
Metrological data
- Capacity
- 100, 200, 300, 500, 750, 1000 Ton
- Accuracy Class
- C1
- Maximum Intervals (nLC)
- 1000
- Minimum Verification Interval
- Emax/5000
- Output Sensitivity (FS)
- 2.00 ± 0.05mV/V
- Zero Balance
- ± 1 %FS
Electrical data
- Input Resistance
- 400 Ω ± 30 Ω
- Output Resistance
- 350 Ω ± 5 Ω
- Isolation Resistance
- ≥ 5000 MΩ (100VDC)
- Excitation, Recommended Voltage
- 10 VDC
- Maximum Excitation Voltage (Umax)
- 15 VDC
Environmental data
- Compansated Temperature
- -10 … +40 °C
- Operating Temperature
- -30 … +70 °C
- Ingress Protection (EN60529)
- IP 66
Mechanical data
- Safe Overload
- 150 % FS
- Ultimate Overload
- 300 % FS
- Element Material
- Alloyed Steel
- Cable
- 4x0.22 mm²
Other
- Minimum Load
- 0 kg
- Total Error
- ±0.05 %FS
Application Area
Application Areas
- Force test machines
- Test machines
- Tank and silo weighing
- Hydrolic systems